beautypg.com

Configuration, Basic configurations – Lenze EVS9332xP User Manual

Page 296

background image

Configuration

Basic configurations

8

8.5

l

8.5−30

EDSVS9332P EN 5.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0685 CMP2−

FUNCTION

1

1
2
3
4
5
6

IN1 = IN2
IN 1 > IN2
IN 1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|

CMP2
Function selection

l

Comparison of inputs IN1
and IN2

See system
manual
(extension)

C0686 CMP2−

HYSTERESIS

1.00

0.00

{0.01 %}

100.00 CMP2

Hysteresis

C0687 CMP2−

WINDOW

1.00

0.00

{0.01 %}

100.00 CMP2

Window

C0688

s

® Selection list 1 CMP2

Configuration of analog input
signals

1 CMP2−IN1

1000

FIXED0%

2 CMP2−IN2

1000

FIXED0%

C0689

g

−199.99

{0.01 %}

199.99 CMP2

Display of analog input signals

1 CMP2−IN1

2 CMP2−IN2

C0690 CMP3−

FUNCTION

1

1
2
3
4
5
6

IN1 = IN 2
IN 1 > IN2
IN 1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|

CMP3
Function selection

l

Comparison of inputs IN1
and IN2

See system
manual
(extension)

C0691 CMP3−

HYSTERESIS

1.00

0.00

{0.01 %}

100.00 CMP3

Hysteresis

C0692 CMP3−

WINDOW

1.00

0.00

{0.01 %}

100.00 CMP3

Window

C0693

s

® Selection list 1 CMP3

Configuration of analog input
signals

1 CMP3−IN1

1000

FIXED0%

2 CMP3−IN2

1000

FIXED0%

C0694

g

−199.99

{0.01 %}

199.99 CMP3

Display of analog input signals

1 CMP3−IN1

2 CMP3−IN2

C0700

s

ANEG1−IN

19523 FCODE−472/3

® Selection list 1 ANEG1

Configuration − analog input
signal

See system
manual
(extension)

C0701 ANEG1−IN

g

−199.99

{0.01 %}

199.99 ANEG1

Display of analog input signal

C0703

s

ANEG2−IN

1000

FIXED0%

® Selection list 1 ANEG2

Configuration − analog input
signal

See system
manual
(extension)

C0704 ANEG2−IN

g

−199.99

{0.01 %}

199.99 ANEG2

Display of analog input signal

This manual is related to the following products: