Configuration, Basic configurations – Lenze EVS9332xP User Manual
Page 303

Configuration
Basic configurations
8.5
l
8.5−37
EDSVS9332P EN 5.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0810
s
® Selection list 1 ASW1
Configuration of analog input
signals
See system
manual
(extension)
1 ASW1−IN1
1000
FIXED0%
2 ASW1−IN2
1000
FIXED0%
C0811
s
ASW1−SET
1000
FIXED0
® selection list 2 ASW1
Configuraton of digital input
signal
C0812
g
−199.99
{0.01 %}
199.99 ASW1
Display of analog input signals
1 ASW1−IN1
2 ASW1−IN2
C0813 ASW1−SET
g
ASW1
Display of digital input signal
C0815
s
® Selection list 1 ASW2
Configuration of analog input
signals
1 ASW2−IN1
1000
FIXED0%
2 ASW2−IN2
1000
FIXED0%
C0816
s
ASW2−SET
1000
FIXED0
® selection list 2 ASW2
Configuraton of digital input
signal
C0817
g
−199.99
{0.01%}
199.99 ASW2
Display of analog input signals
1 ASW2−IN1
2 ASW2−IN2
C0818 ASW2−SET
g
ASW2
Display of digital input signal
C0820
s
® selection list 2 AND1
Configuration of digital input
signals
See system
manual
(extension)
1 AND1−IN
1000
FIXED0
2 AND1−IN
1000
FIXED0
3 AND1−IN
1000
FIXED0
C0821
g
AND1
Display of digital input signals
1 AND1−IN1
2 AND1−IN2
3 AND1−IN3
C0822
s
1000
® selection list 2 AND2
Configuration of digital inputs
See system
manual
(extension)
1 AND2−IN
1000
FIXED0
2 AND2−IN
1000
FIXED0
3 AND2−IN
1000
FIXED0
C0823
g
AND2
Display of digital input signals
1 AND2−IN1
2 AND2−IN2
3 AND2−IN3