Commissioning – Lenze EVS9332xP User Manual
Page 216

Commissioning
Parameter set management
Loading a parameter set
6.12
6.12.2
l
6.12−4
EDSVS9332P EN 5.0−07/2013
Fig. 6.12−3
Read parameter set from controller
How to read a parameter set from the controller:
1. Execute Drive parameters
è Read parameter set from drive.
– Alternatively the command can be executed via key "F7".
2. Select the settings of the parameter set which are to be read in the
parameter set management in C0002.
– Load Lenze setting (C0002 = 0)
– Load customised parameter set (C0002 = 1)
3. The parameter set is read from the controller and is loaded in GDC.
– During the parameter set is loaded, the controller cannot be
operated. The RDY message on the controller is inactive.
Read parameter set from
drive