Configuration, Basic configurations – Lenze EVS9332xP User Manual
Page 278

Configuration
Basic configurations
8.5
l
8.5−12
EDSVS9332P EN 5.0−07/2013
IMPORTANT
Possible settings
Code
Selection
Lenze
Designation
No.
C0183 DIAGNOSTICS
g
Drive diagnostics
l
Indicates fault or status
information
l
Shows the smallest
numerical value if several
pieces of fault or status
information are pending at
the same time
0
OK
No fault
101
Initialisation
Initialisation phase
102
TRIP/fault
TRIP active
103
Emergency stop
Emergency stop was carried out
104
IMP message
Message active
105
Power OFF
Function is not supported
111
BSP C135 operation inhibit
Operation inhibit
112
BSP AIF operation inhibit
113
BSP CAN operation inhibit
121
RSP terminal 28 controller inhibit
Controller inhibited through
X5/28
122
Controller inhibit, internal 1
DCTRL−CINH1
123
Controller inhibit, internal 2
DCTRL−CINH2
124
RSP C135/STOP controller inhibit
STOP key on the keypad
125
RSP AIF controller inhibit
Controller inhibited via AIF
126
RSP CAN controller inhibit
Controller inhibited through
CAN
141
Switch−on inhibit
Restart protection active
142
IMP inhibit pulse inhibit
High resistance power outputs
151
QSP terminal ext. quick stop
Quick stop via MCTRL−QSP
152
QSP−C135 quick stop
Quick stop via STOP key on the
keypad
153
QSP−AIF quick stop
Quick stop via AIF
154
QSP−CAN quick stop
Quick stop via system bus
250
Warning C168
Warning active
C0190 NSET ARIT
0
0
1
2
3
4
5
OUT = C46
C46 + C49
C46 − C49
C46 * C49
C46 / C49
C46/(100 − C49)
NSET
Arithmetic block in the NSET
function block
l
Connects main setpoint
C0046 and additional
setpoint C0040
See system
manual
(extension)
C0195 BRK1 T ACT
99.9
0.0
{0.1 s}
99.9 BRK1
Brake closing time.
Engagement time of the
mechanical holding brake
l
After the time under C0195
has elapsed, the
"mechanical brake closed"
status is reached
See system
manual
(extension)