Installing of the standard device

Standard devices in the power range 0.37 ... 11 kW
Mounting in "cold plate" technique

4

4.1
4.1.4

l

4.1−4

EDSVS9332P EN 5.0−07/2013

4.1.4

Mounting in "cold plate" technique

The drive controllers can be mounted in ˜cold plate˜ technique, e.g. on
collective coolers. For this purpose, the drive controllers of type EVS93xx−CPx
must be used.

Mounting material required from the scope of supply:

Description

Use

Quantity

EVS9321−CP
EVS9322−CP

EVS9323−CP
EVS9324−CP

EVS9325−CP
EVS9326−CP

Fixing bracket

Controller fixing

2

2

2

Sheet metal screw
3.5 × 13 mm (DIN 7981)

Mounting the fixing
bracket to the controller

6

6

6

The following points are important for safe and reliable operation of the
controller:

ƒ Good thermal connection to the cooler

– The contact surface between the collective cooler and the controller

must be at least as large as the cooling plate of the controller.

– Plane contact surface, max. deviation 0.05 mm.
– When attaching the collective cooler to the controller, make sure to

use all specified screw connections.

ƒ Observe the thermal resistance R

th

given in the table. The values are

valid for controller operation under rated conditions.

9300

Cooling path

Power to be dissipated

Heatsink − environment

Type

P

v

[W]

R

th

[K/W]

EVS9321−CP

24

1.45

EVS9322−CP

42

0.85

EVS9323−CP

61

0.57

EVS9324−CP

105

0.33

EVS9325−CP

180

0.19

EVS9326−CP

360

0.10

ƒ The rated data and the derating factors at increased temperature also

apply to the ambient temperature of the drive controllers.

ƒ Temperature at the cooling plate of the drive controller: max. 75 °C.

Requirements for collective
coolers

Ambient conditions

This manual is related to the following products: