beautypg.com

Controlling the drive, Commissioning, 14 controlling the drive – Lenze EVS9332xP User Manual

Page 221

background image

Commissioning

Controlling the drive

6

6.14

l

6.14−1

EDSVS9332P EN 5.0−07/2013

6.14

Controlling the drive

1

2

3

4

5

6

8

9

7

Fig. 6.14−1

"Control" dialog box

Procedure

1.

Click on the "Control" button in the "Basic settings" dialog box to open the "Control"
dialog box.

2.

Activate the program operation.

l

Lenze setting: Set X5/E5 = HIGH.

l

"Manual operation" (1) must be deselected.

3.

Click "Start" (4) to enable the controller.

l

If "Ok" is displayed in the "Drive diagnostics" field (5), enable can be executed.

l

Controller inhibit must be deactivated (X5/28 = HIGH).

4.

Control the drive.

l

The "Controller" field (6) shows the current positioning and the program status.

A

Select "Program start" (9).

l

The drive moves according to the loaded positioning profile.

B

Deselect "Program start" (9) and select it again.

l

The program restarts or is continued after an interruption ("Program stop").

C

Select "Program stop" (8).

l

The program execution is interrupted. The drive stops.

D

Deselect "Program stop" (8).

l

The program execution can be continued with "Program start".

E

Select "Program reset" (7).

l

The program execution is aborted. The drive stops. The piece counter and all PFOs
are reset. (

^ 6.11−1)

F

Deselect "Program reset" (7).

l

The first PS with which the program is to start is loaded.

l

The program can be restarted with "Program start".

Via the "Control" dialog box you can start, stop, and reset the positioning
program and read the current program status.

This manual is related to the following products: