IC/5 Operating Manual
MAX POWER REACHED 1 (2)
Indicates the specified maximum power has been reached on an active
source in the primary (1) or secondary (2) layer.
MAXIMUM TERMS
No more than 5 terms are allowed in anyone Event or Action string.
MEM ALLOC FAIL
This message appears if a Data Log or Print Screen operation fails because of
an overuse of system memory. If this message appears contact the INFICON
Service Department.
MENU UNAVAILABLE
Indicates the menu tree cannot be accessed from the instrument’s current
display because Lock Codes have been programmed.
MUST EDIT NAME FIRST
The user requested a save name or save message operation without first
having edited the name or message.
MUST ENTER OLD CODE
Utility Set-Up requires the user to enter the old Program or I/O Lock Code
before updating to a new Program or I/O Lock Code.
MUST SET TAG(S)
The user may not perform a copy or delete operation without first “tagging” the
layer(s) to be copied or deleted.
MUST USE 1 SENSOR
At least one sensor for each defined Material must have its Option parameter
non-zero.
NO DISK IN DRIVE
Save or Retrieve requires a floppy disk to be inserted: the disk is not detected
by the instrument.
NO MATERIAL DEFINED
Materials must be defined to be used in a Process Layer.
NON-DEPOSIT HOLD
Indicates the non-deposit hold Action is activated. Shown in reverse video.
NO SOURCE DAC
A DAC output must be defined in the Source Set-Up display in order to
execute a process using the requested source. The source is requested on
page 1 of the Material Set-Up display; the DAC output associated with this
source is defined in the Source Set-Up display.
NO SWITCH: IN LAYER
A crystal switch from the Hand-Held Controller cannot be done while a layer is
running.