beautypg.com

Stabil-trak™ system – Lull 944E-42 Service Manual User Manual

Page 796

background image

Stabil-TRAK™ System

10.38

Model 644E-42/944E-42

Rev. 6/04

10.8.9

Hydraulic Circuit Operation - Slow Pivot Mode, Base Oil Out

Conditions:

• Boom angle is above 40° OR

(On SN 0160003881 & Before Only) below 40°

• Park brake OFF

• Service brake DISENGAGED OR

(On SN 0160003881 & Before Only) with enough
pedal movement to produce required pressure in
brake system

• Travel select lever in (F) FORWARD or (R) REVERSE

position

Operation:

As the boom is raised above 40°, the boom proximity
switch is deactivated causing solenoids 12A and 12B to
de-energize and solenoids 4A and 4B to energize. This
allows oil to flow from the base end of the stabilizer
cylinder (1), through solenoid-operated valve 4A (2),
through a .060" orifice (3), through another .060" orifice (4),
then through solenoid-operated valve 4B (5), to the rod
end of the stabilizer cylinder.

The .060" orifices (3 and 4) in solenoid-operated valves
4A and 4B will slow the movement of the rear axle in
reaction to terrain changes. The frame sway will react
normally in this mode.

Because of the greater volume of oil in the base end,
extra oil is returned to the tank through the 100 psi (7 bar)
reducing cartridge (6) in the Stabil-TRAK™ manifold. The
restrictions produce the slow movement, or SLOW PIVOT
mode.

Suction

Return

Load Sense

Pressure

Pilot Pressure

HYDRAULIC

RESERVOIR

ACCUMULATOR

CHARGE/SECONDARY

FUNCTION VALVE

LS

DRAIN

P1

LSG

ACR

SW

P

ACF

EF

CF

PIL

PB

PBG

PPG

SW

HYDRAULIC OIL

COOLER

FRAME SWAY

JOYSTICK

CHECK

VALVE

FITTING

CHECK

VALVE

FITTING

SOLENOID COIL

STATE

ENERGIZED

DE-ENERGIZED

E

DE

Ø .041

P

T

2

1

ATTACH

TILT

FRAME

EXT/RET

LFT/LWR

AU

X

TRANS

MAIN CONTROL

VALVE

INLET

OUTLET

PUMP

Ø .048

FRAME

SWAY

CYLINDER

FTR

FTB

STABILIZER

CYLINDER

.060 DIA.

FTR

P

T

V

G3

G2

G1

4A

4B

12B

3

2B

2A

12A

.060 DIA.

.030 DIA.

100 PSI

STABIL-TRAK

TM

MANIFOLD

DE

E

DE

E

DE

200

PSI

MU4801

2

3

1

4

6

5

This manual is related to the following products: