8.17

Model 644E-42/944E-42

Rev. 6/04

Hydraulic System

Engine Information

Idle . . . . . . . . . . . . . . . . . . . . . . . 950 ±50 rpm
Full Speed . . . . . . . . . . . . . . 2,650 ±100 rpm

Hydraulic Oil Information

Oil Type - 10W, meet ISO Grade 46
Capacity - Reservoir . . . . . 33.5 gal. (127 liter)
Capacity - System . . . . . . 50.2 gal. (190 liter)
Note: To adjust relief settings, pressure reducing
settings or standby pressure, turn the
adjustment screw clockwise to increase
pressure or counterclockwise to decrease
pressure.
The hydraulic oil temperature for the pump flow
test should be between 100-120° F (38-49° C)
(tank hot to the touch) during testing.

Equipment Needed to Perform Tests

from Hydraulic Diagnostic Test Kit

Test Location

Gauge

Fittings

4,000 psi gauge
(280 bar gauge)

Unit equipped with fittings from
factory.

1,000 psi gauge

(70 bar gauge)

Unit equipped with fittings from
factory.

300 psi gauge

(21 bar gauge)

Requires a #4 o-ring Boss Fitting
with Diagnostic Nipple.

2

5

6

4

7

8

3

9

10

CAUTION:

GAUGE DAMAGE may occur. Malfunctioning hydraulic system

circuits may have excessive pressure and can cause hydraulic pressure spikes.
Test circuit with the highest reading pressure gauge first. If this gauge cannot
record an accurate pressure reading, use the next lower pressure gauge.

TEST

SEQUENCE

TEST

LOCATION

Hydraulic Pump Flow Test

1

To check flow readings, a flow meter capable of measuring 60 gpm (227,1 liter/min) and a load valve
capable of 6,000 psi (413,4 bar) will be required (not included with Hydraulic Diagnostic Test Kit).

Test both pump sections of the tandem gear pump separately. Test the primary pump section first. When testing
the pump sections, return the oil from the flow meter directly into the hydraulic tank fill hole.
Run test at 2,000 psi (137,8 bar) load @ Engine Speed of 2,500 ±25 rpm.

PRIMARY PUMP (pump section closest to the transmission) - Label and disconnect the outlet hose from the
primary pump and allow the hose to hang loose. Cover, cap or plug the primary pump outlet hose to prevent
contamination of the hydraulic system. Connect the flow meter to the outlet port on the primary pump — Flow rate
should be 16.5-19.5 GPM (62,5-73,8 liter/min).

SECONDARY PUMP (pump section furthest from the transmission) - Label and disconnect the outlet hose
from the secondary pump and connect to the outlet port on the primary pump. Connect the flow meter to the outlet
port on the secondary pump — Flow rate should be 13.2-15.5 GPM (49,9-58,7 liter/min).

IMPORTANT: When testing on the secondary pump is completed make sure to disconnect the secondary pump
outlet hose from the primary pump outlet port and reconnect it to the secondary pump outlet port. Also make sure
to re-connect the primary pump outlet hose to the primary pump outlet port.

TEST

SEQUENCE

TEST

LOCATION

Valve

Port

ADJUST.

LOCATION

COMPONENT

DESCRIPTION

PRESSURE

READINGS

PRESSURE TEST PROCEDURES

2

N/A

Stand By
Pressure

200 ±25 psi

(13,8 ±1,7 bar)

With engine at idle, check the pressure. The pressure is not
adjustable. If the pressure is incorrect, replace unloader
cartridge

on Main Control Valve.

3

PPG

Pilot Valve

Pressure

500-600 psi

(34,5-41,4 bar)

With engine at idle, check the pressure. If the pressure is
incorrect, adjust or replace the pressure reducing cartridge
located on the accumulator charge/secondary function valve.

4

PBG

Accumulator

Charge/

Secondary

Function Valve

Park Brake

Release

500-600 psi

(34,5-41,4 bar)

With engine at idle, turn the park brake switch to the disengaged
position. Check the pressure. If the pressure is incorrect, adjust
or replace the pressure reducing cartridge located on the
accumulator charge/secondary function valve.

5

P1

Power Steering

Supply

2,400-2,600 psi

(165-179 bar)

With engine at idle, turn the steering wheel all the way in one
direction and hold while checking pressure. If pressure is
incorrect, adjust or replace the relief valve located on the
accumulator charge/secondary function valve.

6

SW

N/A

Accumulator

Charge/

Secondary

Function Valve

See “Pressure

Test Procedures”

for Pressure

Readings

At start up, the pressure should jump up to and stop
momentarily at 450 psi (31 bar), which is the pre-charge
pressure. The pressure should then continue to rise to 1,900-
2,100 psi (131-145 bar) which is the accumulator charge
pressure. Let the system bleed down naturally with the engine
at idle (minimum of 2 minutes). The accumulator charge
pressure should recharge at 1050 ±50 psi (72 ±3,4 bar).

7

Main System

Relief

3,400-3,600 psi

(234-248 bar)

With engine at high idle, use the boom control lever to fully
retract the boom. Hold over relief and check pressure. If
pressure is incorrect, adjust or replace cartridge located in the
end section of the main control valve.

1a

1b

10

8

3

1

4

1

5

2

6

2

3