6.7.8
Special codes
Some parameters can be configured by inserting a special code.
Go to the page for inserting special codes (see § 6.1.5 - Layout of the configuration menus, page 76) and
insert the numeric values using the keypad.
Code
Function
AUTOPAN
1
Considers the current position as the first limit switch
2
Considers the current position as the second limit switch
3
The dome goes to the position of the first limit switch.
4
The dome goes to the position of the second limit switch..
AUTOFLIP
5
Enables the AUTOFLIP function.
6
Disables the AUTOFLIP function.
PATROL
21
Starts PATROL sequence 1. Equivalent to the corresponding key in the PATROL menu.
22
Starts PATROL sequence 2. Equivalent to the corresponding key in the PATROL menu.
23
Starts PATROL sequence 3. Equivalent to the corresponding key in the PATROL menu.
ON SCREEN INFORMATION
7
Enables “TITLE AREA ” display
8
Disables “TITLE AREA ” display
9
Enables on screen display of information relating to the camera
10
Enables on screen display of service information
11
Disables all on screen display of information
12
Enables “EVENT DISPLAY MODE”
13
Disables “EVENT DISPLAY MODE”
ZOOM SPEED
7X
X = 1 ÷ 4: (1 = minimum, 4 = maximum)
FOCUS SPEED
8X
X = 1 ÷ 4: (1 = minimum, 4 = maximum)