beautypg.com

Videotec DCT User Manual

Page 132

background image

6.17.5

Patrol

In the Main menu press the PATROL to enter the menu for carrying out the specific function.

START PATROL / RANDOM
To start the corresponding function.

STOP PATROL / RANDOM
To stop the corresponding function.

SETUP PATROL / RANDOM
To enter the setup menu for the corresponding
function.

6.17.5.1

Setup Standard PATROL

The PATROL sequence comprises a series of Preset positions that are reached in succession with the same
dwell time for each position. The Standard PATROL can have a maximum of 64 positions.

Proced

ure for defining a PATROL:

Select field 1, press the “

ent

” key set and insert the number of the desired Preset position.

Select field 2, press the “

ent

” key set and insert the number of the desired Preset position.

Select field 3, press the “

ent

” key set to send the configuration to the receiver.

Select field 4, press the “

ent

” key set and insert the desired dwell time.

Select field 5, press the “

ent

” key set and insert the desired speed value.

Select field 6, press the “

ent

” key set and insert the desired speed value.

Press the “

esc

” key to return to the PATROL page

Page 130 of 176

MNVADCT03_0716