Table 2
DCT
RJjack1
RJjack2
MTX
MTX – DVR/MUX
GENERAL INDIRECT connection diagram
RS485A
white
blue
RS485A
GND
red
green
GND
RS485B
yellow
black
RS485B
See the matrix
handbook.
Table 3
DIRECT CONNECTION
DVR model
Type
Protocol
Baud rate
Address
Ext. DVR/MUX
ENEO
DLR-204/109/116
DVR/MUX ENEO DLR-204/109/116 300-38400
(1)
-------------------
SAMSUNG
SHR4160P
DVR/MUX SAMSUNG DVR
4800-38400
(1)
-------------------
SANYO
DSR-3009P
DSR-3016P
DSR-3716P
DVR/MUX
SANYO DVR or
SANYO DVR/MU
2400-19200 0..4
(2)
-------------------
SONY
HSR-X216P
DVR/MUX SONY DVR
2400-19200 0..4
(2)
-------------------
MUX model
Type
Protocol
Baud rate
Address
Ext. DVR/MUX
ADEMCO
AXMD16E / AXCD16EX
DVR/MUX ADEMCO MUX
1200-19200
(1)
-------------------
ENEO
VCMT-8009/8016
VBMT-8009/8016
DVR/MUX
ENEO MUX VCM
ENEO MUX VBM
1200-9600
(1)
-------------------
SANYO
MPX-CD93P
MPX-CD163P
DVR/MUX
SANYO MUX or
SANYO DVR/MU
2400-19200 0..4
(2)
-------------------
SONY
YS-DX516P
DVR/MUX SONY MUX
2400-19200 0..4
(2)
-------------------
VIDEOTEC
SP16C
DVR/MUX
SP16C or
SP16C-A (addressable)
1200-9600
(3)
-------------------
(1)
It is possible to connect more than one keyboard to each DVR/MUX; the identification address of the keyboard is
irrelevant. More than one DVR/MUX can be controlled by the same keyboard, as long as they are identified by
different unit addresses.
(2)
It is possible to connect at most 5 keyboards to each DVR/MUX; the identification address of the keyboard should
be between 0 and 4. More than one DVR/MUX can be controlled by the same keyboard, as long as they are
identified by different unit addresses.
(3)
It is possible to connect more than one keyboard to each MUX; the identification address of the keyboard is
irrelevant. More than one MUX can be controlled by the same keyboard only if they are addressable and on
condition that they are identified by different unit addresses.
WARNING (INDIRECT connection)
Consult the handbook of the matrix you are using to make sure it is able to manage the protocol used
by the DVR/MUX's connected in cascade.