17 eneo receivers – Videotec DCT User Manual
Page 131

6.17 ENEO receivers
6.17.1
Reference material
ENEO VPT-42/RS1 telemetry receiver..
6.17.2
Configuring the receivers
Configure the receiver appropriately as described in the corresponding handbook.
Some parameters can be configured by inserting a special code (see § 6.1.5 - Layout of the configuration
menus, page 76).
Refer to the relevant section (see § 6.19 - Operating procedure for setting a dome/receiver, page 137).
6.17.3
Connecting the hardware
ENEO receivers can be connected directly to the keyboard using one of the telephone cables supplied with the
keyboard (for testing and control) or using the standard connection cable, which can reach distances of up to
1200 m (see § 3.3 - One keyboard per line: standard connection cable, page 15).
6.17.4
Autopan, Aux, Focus, Iris
All these functions can be loaded by pressing the specific keys in the control menu area of the Main menu (see
§ 4.4 – Control menu area, page 45).
Refer to § 9.1 – Functions assigned to the most common graphics keys, page 164 e § 9.2.2 – Telemetry
receivers, page 167 to check which functions are available for the receiver.
6.17.4.1
Autopan
For correct Autopan operation the Preset position Nos. 63 and 64 must always be assigned
settings because they define the two AUTOPAN limit switch positions.
6.17.4.1.1
Setup AUTOPAN
Pro
cedure for defining the AUTOPAN function:
Select field 1, press the “
ent
” key and insert the desired speed value (1 = minimum speed, 255 =
maximum speed).
Select field 2, press the “
ent
” key and insert the value for the AUTOPAN function duration (expressed in
minutes).
A setting of 255 will allow the system to operate without time limits.
Press the “
esc
” key to return to the AUTOPAN page.
Page 129 of 176
MNVADCT03_0716