Code
Function
54
Toggle masking (ON/OFF) depending on cursor status:
Cursor ON: the code will position a small mask on the cursor; if the code is sent again, the
type of masking will change.
Cursor OFF: the code will mask the complete area of the screen; if the code is sent again
the masking will be removed.
DYNAMIC CONTROL OF ZONE TITLING
61
Toggle titling (ON/OFF)
62
Clear Zone
63
Reset Zone (initialisation)
DIGITAL ZOOM
6
Toggle digital Zoom (ON/OFF)
1XX
XX = 00 ÷ 99: digital zoom value (if the function is available on the dome)
TOGGLE AUTO PARK (ON/OFF)
2XX
It is possible to set up the dome so that it moves automatically to Preset position No. 1 after
a given period of inactivity.
XX = 00 c÷99 (*): Waiting time (minutes) before Auto Park
(*) A waiting time of XX = 00 disables the function
Example
“205” Auto Park after a wait of 5 minutes (XX = 05)
“200” Auto Park OFF (XX = 00)
TOGGLE AUTO PATROL (ON/OFF)
1XXY
It is possible to set up the dome so that it starts a certain Patrol sequence after a given
period of inactivity.
XX = 00 ÷ 99 (*): Waiting time (minutes) before Auto Patrol
Y = 0 ÷ 5: Patrol number
(*) A waiting time of XX ÷ 00 disables the function
Example
“1153” Auto Patrol after 15 minutes (XX = 15) with activation of sequence No. 3 (Y = 3)
“1003”Auto Patrol OFF (XX = 00)
OTHER CODES
0
Patrol through all positions
1
Toggle Auto U-Turn (ON/OFF)
2
Aux 1 ON
3
Aux 1 OFF
7
On-board alarms: ON
8
On-board alarms: OFF
10
U-Turn
Page 107 of 176