3 noise – Yaskawa SGDS Sigma III Servo Amplifier User Manual
Page 55

2 System Selection
2.5.3 Noise Filters, Magnetic Contactors, Surge Protectors and AC/DC Reactors
2-26
2.5.3 Noise Filters, Magnetic Contactors, Surge Protectors and AC/DC Reactors
Note: 1. If some SERVOPACKs are wired at the same time, select the proper magnetic contactors
according to the total capacity.
2. The following table shows the manufacturers of each device.
Main Circuit
Power
Supply
SERVOPACK Model
Recommended Noise Filter
(Refer to 4.4.6)
Magnetic
Contactor
(Refer to
Surge
Protector
(Refer to
AC/DC
Reactor
(Refer to
Capacity
(kW)
SGDS-
Type
Specifications
Single-phase
100 V
0.05
A5F
FN2070-6/07
Single-phase
250 VAC, 6 A
HI-11J (20 A)
R C M
-601BQZ-4
X5053
0.10
01F
0.20
02F
FN2070-10/07
Single-phase
250 VAC, 10 A
X5054
0.40
04F
FN2070-16/07
Single-phase
250 VAC, 16 A
HI-15J (35 A)
X5061
Single-phase
200 V
0.05
A5A
FN2070-6/07
Single-phase
250 VAC, 6 A
HI-11J (20 A)
X5052
0.10
01A
0.20
02A
X5053
0.40
04A
FN2070-10/07
Single-phase
250 VAC, 10 A
X5054
0.80
08A
FN2070-16/07
Single-phase
250 VAC, 16 A
HI-15J (35 A)
X5056
Three-phase
200 V
1.0
10A
FN258L-16/07
Three-phase
250 VAC, 16 A
R C M
-601BUZ-4
X5061
15
15A
Consult
Factory
2.0
20A
Consult
Factory
3.0
30A
Fn258L-30/07
Three-phase
480VAC, 30A
HI-18J (50 A)
Consult
Factory
Peripheral Device
Manufacturer
Noise Filter
Schaffner Electronic
Magnetic Contactor
Yaskawa Siemens Automation & Drives Corp.
Surge Protector
Okaya Electric Industries Co., Ltd.
AC/DC Reactor
Yaskawa Controls Co., Ltd.