6 MECHATROLINK II Communications
6.4.1 No Operation (NOP: 00H)
6-44
6.4 Subcommands
This section describes the subcommands for SGDS-
12A SERVOPACK. The MECHATROLINK II sub-
commands can be used for MECHATROLINK II communications by specifying them with the CONNECT com-
mand.
They use the seventeenth to the twenty-ninth bytes of the command and response data. (They cannot be used with
MECHATROLINK.)
6.4.1 No Operation (NOP: 00H)
6.4.2 Read Parameter (PRM_RD: 01H)
Byte
NOP
Description
Command
Response
Processing
classifications
Network com-
mand group
Processing time
Within communi-
cations cycle
17
00H
00H
• Not operation command.
• This command can be used with any main commands.
18
Substatus
19
20
21
22
23
24
25
26
27
28
29
Byte
PRM_RD
Description
Command
Response
Processing
classifications
Network com-
mand group
Processing time
Within 6 ms
17
01H
01H
• Reads the parameters. This command has the same function as the main
command PRM_RD.
• This command can be used only with the following main commands:
NOP, ID-RD, HOLD, LTMOD_ON/OFF, SMON, SV_ON/OFF,
INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL,
TRQCTRL
18
Substatus
19
NO
NO
20
21
SIZE
SIZE
22
PARAMETER
23
24
25
26
27
28
29