10.2 Inspection and Maintenance

10-25

10.2 Inspection and Maintenance

10.2.1 Servomotor Inspection

The AC servomotors are brushless. Simple, daily inspection is sufficient. The inspection and maintenance fre-
quencies in the table are only guidelines. Increase or decrease the frequency to suit the operating conditions and
environment.

During inspection and maintenance, do not disassemble the servomotor. If disassembly of the servomotor is
required, contact your Yaskawa representative.

* Measure across the servomotor FG and the phase-U, phase-V, or phase-W power line.

10.2.2 SERVOPACK Inspection

For inspection and maintenance of the SERVOPACK, follow the inspection procedures in the following table
at least once every year. Other routine inspections are not required.

Table 10.6 Servomotor Inspections

Item

Frequency

Procedure

Comments

Vibration and Noise

Daily

Touch and listen.

Levels higher than normal?

Exterior

According to degree
of contamination

Clean with cloth or compressed
air.

Insulation Resistance
Measurement

At least once a year

Disconnect SERVOPACK and
test insulation resistance
at 500 V. Must exceed 10 M

Ω .

Contact your Yaskawa
representative if the insulation
resistance is below 10 M

Ω .

Replacing Oil Seal

At least once every
5000 hours

Remove servomotor from
machine and replace oil seal.

Applies only to motors with
oil seals.

Overhaul

At least once every
20000 hours or 5
years

Contact your Yaskawa
representative.

The user should not
disassemble and clean the
servomotor.

IMPORTANT

Table 10.7 SERVOPACK Inspections

Item

Frequency

Procedure

Comments

Clean Interior and
Circuit Boards

At least once a year

Check for dust, dirt, and oil
on the surfaces.

Clean with compressed
air.

Loose Screws

At least once a year

Check for loose terminal
block and connector
screws.

Tighten any loose screws.

Defective Parts in
Unit or on
Circuit Boards

At least once a year

Check for discoloration,
damage or discontinuities
due to heating.

Contact your Yaskawa
representative.