6.3 Main Commands
6-15
6.3.9 MECHATROLINK II Connection (CONNECT: 0EH)
• Details of COM_MOD
* If SYNCMOD = 0, the SERVOPACK transmits the SYNC_SET command and changes the
communications to Phase 3.
Byte
CONNECT
Description
Command
Response
1
0EH
0EH
Processing
classifications
Network com-
mand group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Communications
cycle or more
Subcommand
Cannot be used
3
STATUS
• Establishes a MECHATROLINK II connection. Sets the communications
mode according to COM_MOD.
• VER: Version
• Set VER to 21H (Ver. 2.1).
• COM_MOD: Communications mode. Refer to the following table.
• COM_TIM: Communications cycle
Set the multiple number of transmission cycle in the range of 0.5 to 32.
When the transmission cycle is 0.5 [ms]
≤ transmission cycle [ms] ×
COM_TIM
≤ 32 [ms] and the communications cycle is set in multiples of 0.5
ms.
• A warning will occur and the command will be ignored in the following cases.
- If COM_MOD is not within range: Data setting warning 2 (A.94B)
- If COM_TIM is not within range: Data setting warning 2 (A.94B)
- If the transmission bytes is 17, and SUBCMD is 1: Data setting
warning 2 (A.94B)
- If VER is not equal to 21H in the MECHATROLINK communications
mode: Data setting warning 2 (A.94B)
4
5
VER
VER
6
COM_MOD
COM_MOD
7
COM_TIM
COM_TIM
8
9
10
11
12
13
14
15
16
WDT
RWDT
D7
D6
D5
D4
D3
D2
D1
D0
SUBCMD
0
0
0
DTMOD
SYNCMOD
0
• SYNCMOD*:
0: Asynchronous communication
1: Synchronous communication
DTMOD: Data transfer method
00, 11: Single transfer
01: Consecutive transfer
SUBCMD:
0: Subcommand not used
1: Subcommand used
• Set the 0 in the other bit.
Phase 1
Phase 2
Phase 3
SYNCMOD=0
SYNC_SET
Warning/alarm
SYNCMOD=1