9) less deviation control related parameters, 34 (9) less deviation control related parameters – Yaskawa SGDS Sigma III Servo Amplifier User Manual
Page 261

8 Adjustments
8.6.6 Switching Gain Settings
8-34
(9) Less Deviation Control Related Parameters
Pn1A0
Servo Rigidity
Setting Range
Setting Unit
Factory Setting
Setting Validation
1% to 500%
1%
60%
Immediately
Pn1A1
Servo Rigidity 2
Setting Range
Setting Unit
Factory Setting
Setting Validation
1% to 500%
1%
60%
Immediately
Pn1A2
Speed Feedback Filter Time Constant
Setting Range
Setting Unit
Factory Setting
Setting Validation
0.30 to 32.00 ms
0.01 ms
0.72 ms
Immediately
Pn1A3
Speed Feedback Filter Time Constant #2
Setting Range
Setting Unit
Factory Setting
Setting Validation
0.30 to 32.00 ms
0.01 ms
0.72 ms
Immediately
Pn1A7
Auxiliary Control Switches
Setting Range
Setting Unit
Factory Setting
Setting Validation
−
−
1121
Immediately
Speed
Position
Speed
Position
Speed
Position
Speed
Position
Speed
Position
Parameter
Function
Pn1A7
n.
0
Do not perform integral compensation processing.
n.
1
Perform integral compensation processing. (Factory setting)
n.
2
Use gain switching without position error.
Perform integral compensation on Gain Settings 1.
Do not perform integral compensation on Gain Settings 2.
n.
3
Use gain switching without position error.
Do not perform integral compensation on Gain Settings 1.
Perform integral compensation on Gain Settings 2.