33 general-purpose servo control (svctrl: 3fh), 33 general-purpose, 33 general-purpose servo control (svctrl: 3fh) -41 – Yaskawa SGDS Sigma III Servo Amplifier User Manual
Page 172

6.3 Main Commands
6-41
6.3.33 General-purpose Servo Control (SVCTRL: 3FH)
• Sub-control: SUBCTRL
Select Latch Signal: LT_SGN
Byte
SVCTRL
Description
Command
Response
1
3FH
3FH
Processing
classifications
Compound com-
mand group
Synchronization
classifications
Synchronous,
asynchronous
2
SUBCTRL
ALARM
Processing time
Depends on pro-
cessing
Subcommand
Can be used
3
OPTION
STATUS
• This command is compatible with MECHATROLINK versions before Ver 1.0.
It is used to perform the general-purpose servo control.
• Latch Processing:
Supported. Select the latch signal using L_SGN in the SUBCTRL and set
SET_L to 1. When the selected latch signal is input, L_CMP in STATUS will
become 1. Perform latch processing again after the SET_L command is set to
0. The latch signal cannot be changed while SET_L is set to 1.
• Motion:
Any of the motions listed in the following table can be executed. Refer to
each motion item for operating specifications.
• Sequence Signals:
Any of the sequence signals listed in the following table can be executed.
Refer to each sequence item for operating specifications.
• During phase 1; Command warning 1 (A.95A). A command warning will
occur and the command will be ignored in the following cases.
4
5
TPOS
MONITOR1
6
7
8
9
TSPD
MONITOR2
10
OR
11
VFF
12
13
SEL_MON 1/2
SEL_MON 1/2
14
SQ_CMD
I/O_MON
15
16
WDT
RWDT
17
For
subcommands
use. Refer to
6.4
Subcommands.
For
subcommands
use. Refer to
6.4
Subcommands.
18
19
20
21
22
23
24
25
26
27
28
29
D7
D6
D5
D4
D3
D2
D1
D0
RESERVE
0
MOTION
Select motion
RESERVE
0
SET_L
Latch
command
L_SGN
Select latch signal
D1
D0
Latch Signal
0
0
Phase C
0
1
EXT1
1
0
EXT2
1
1
EXT3