6 MECHATROLINK II Communications

6.5.4 Monitor Selection and Monitor Information Field Specifications: SEL_MON1/2/3/4, MONITOR1/2/3/4

6-52

6.5.4 Monitor Selection and Monitor Information Field Specifications:

SEL_MON1/2/3/4, MONITOR1/2/3/4

The monitor selection and monitor information field specifications (SEL_MON1/2/3/4, MONITOR1/2/3/4) can
be designated using the following main commands:
SV_ON, SV_OFF, HOLD, INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VCELCTRL,
TRQCTRL, SMON, SENS_ON, SENS_OFF, BRK_ON, BRK_OFF, LTMOD-ON, LTMOD-OFF
The monitor selection and monitor information field is used to select the Servo monitor information and monitor
it, with the thirteenth byte of the above main commands, or the nineteenth byte reserved area of the
subcommands.

• SEL_MON1/2/3/4 Field

• MONITOR1/2/3/4 Monitor Codes

D11

NEAR

Positioning proximity

0

Out of positioning proximity
range

Position
control mode

1

Within positioning proximity
range

V_LIM

Speed limit

0

Speed limit not detected

Torque
control mode

1

Speed limit detected

D12

P_SOT

Forward software limit

0

Out of range

1

Within range

D13

N_SOT

Reverse software limit

0

Out of range

1

Within range

D14

Reserved

D15

Reserved

(cont’d)

Bit

Name

Description

Set

Value

Details

Control

Mode

D7

D6

D5

D4

D3

D2

D1

D0

SEL_MON2

SEL_MON1

D7

D6

D5

D4

D3

D2

D1

D0

SEL_MON4

SEL_MON3

Monitor
Codes*

Name

Description

Unit

0

POS

Reference position in the reference coordi-
nate system (position after reference filter
procedure)

Reference units

1

MPOS

Reference position in the mechanical coordi-
nate system

Reference units

2

PERR

Position error

Reference units

3

APOS

Feedback position in the mechanical coordi-
nate system

Reference units

4

LPOS

Feedback latch position in the mechanical
coordinate system

Reference units

5

IPOS

Reference position in the reference coordi-
nate system (position before reference filter
procedure)

Reference units

6

TPOS

Target position in the reference coordinate
system