25 positioning (posing: 35h), 25 positioning (posing: 35h) -31 – Yaskawa SGDS Sigma III Servo Amplifier User Manual
Page 162

6.3 Main Commands
6-31
6.3.25 Positioning (POSING: 35H)
• Related Parameters
Byte
POSING
Description
Command
Response
1
35H
35H
Processing
classifications
Motion command
group
Synchronization
classifications
Asynchronous
2
ALARM
Processing time
Within communi-
cations cycle
Subcommand
Can be used
3
OPTION
STATUS
• Performs positioning at the target position (TPOS) using the target speed
(TSPD).
• Can be used during phases 2 and 3.
• A warning will occur and the command will be ignored in the following cases.
- During phase 1: Command warning 1 (A.95A)
- If the SERVOPACK is Servo OFF: Command warning 1 (A.95A)
- If the target speed (TSPD) exceeds the limit: Data setting warning 2 (A.94B)
• OPTION field can be selected. Refer to 6.5.2 Option Field Specifications:
OPTION for details.
• The target position (TPOS) is a signed 4 bytes. It is set using an absolute
position in the reference coordinate system.
• The target speed (TSPD) is an unsigned 4 bytes. Setting ranges from 0 to the
limit value [reference unit/s].
• Changes can be made to the target position and target speed during movement.
• Use DEN (output complete) to confirm the completion of position reference
output.
4
5
TPOS
MONITOR1
6
7
8
9
TSPD
MONITOR2
10
11
12
13
SEL_MON 1/2
SEL_MON 1/2
14
IO_MON
15
16
WDT
RWDT
17
For
subcommands.
Refer to 6.4
Subcommands.
For
subcommands.
Refer to 6.4
Subcommands.
18
19
20
21
22
23
24
25
26
27
28
29
Pn No.
Description
Pn80A
First-step Linear Acceleration Parameter
Pn80B
Second-step Linear Acceleration Parameter
Pn80C
Acceleration Parameter Switching Speed
Pn80D
First-step Linear Deceleration Parameter
Pn80E
Second-step Linear Deceleration Parameter
Pn80F
Deceleration Parameter Switching Speed