8.6 Servo Gain Adjustment Functions
8-41
Pn1A2
Speed Feedback Filter Time Constant
Setting Range
Setting Unit
Factory Setting
Setting Validation
0.30 to 32.00 ms
0.01 ms
0.72 ms
Immediately
Pn1A3
Speed Feedback Filter Time Constant #2
Setting Range
Setting Unit
Factory Setting
Setting Validation
0.30 to 32.00 ms
0.01 ms
0.72 ms
Immediately
Pn1A4
Torque Reference Filter Time Constant
Setting Range
Setting Unit
Factory Setting
Setting Validation
0.00 to 25.00 ms
0.01 ms
0.36 ms
Immediately
Pn1A9
Auxiliary Integral Gain
Setting Range
Setting Unit
Factory Setting
Setting Validation
0 to 500 Hz
1 Hz
37 Hz
Immediately
Pn1AA
Position Proportional Gain
Setting Range
Setting Unit
Factory Setting
Setting Validation
0 to 500 Hz
1 Hz
60 Hz
Immediately
Pn1AB
Speed Integral Gain
Setting Range
Setting Unit
Factory Setting
Setting Validation
0 to 500 Hz
1 Hz
0 Hz
Immediately
Pn1AC
Speed Proportional Gain
Setting Range
Setting Unit
Factory Setting
Setting Validation
0 to 2,000 Hz
1 Hz
120 Hz
Immediately
Pn10B
Gain-related Application Switches
Setting Range
Setting Unit
Factory Setting
Setting Validation
−
−
0000
After restart
Pn1A7
Auxiliary Control Switches
Setting Range
Setting Unit
Factory Setting
Setting Validation
−
−
1121
Immediately
Position
Position
Position
Position
Position
Position
Position
Position
Position