11 backlash compensation, 1) pn207=o1oo, 2) pn207=o2oo – Yaskawa SGDS Sigma III Servo Amplifier User Manual
Page 276: 12 position integral

8.6 Servo Gain Adjustment Functions
8-49
8.6.11 Backlash Compensation
(1) Pn207= 1
The Backlash Compensation Amount (Pn214) is added to forward reference.
(2) Pn207= 2
The Backlash Compensation Amount (Pn214) is added to reverse reference.
8.6.12 Position Integral
Pn214
Backlash Compensation Amount
Setting Range
Setting Unit
Factory Setting
Setting Validation
-32767 to 32767
reference units
Reference unit
0 reference units
Immediately
Pn215
Backlash Compensation Time Constant
Setting Range
Setting Unit
Factory Setting
Setting Validation
0.00 to 655.35 ms
0.01 ms
0.00 ms
Immediately
Position
Position
Parameter
Meaning
Pn207
n. 0
Disabled. (Factory Setting)
n. 1
Compensate in forward direction.
n. 2
Compensate in reverse direction.
Pn214
Pn214
Machine
Motor shaft
Forward direction
Machine
Motor axis
Pn214
Pn214
Machine
Motor shaft
Reverse direction
Machine
Motor axis
Pn11F
Position Integral
Setting Range
Setting Unit
Factory Setting
Setting Validation
0.0 to 5000.0 ms
0.1 ms
0.0 ms
Immediately
This function adds an integral control operation to the position loop. It is effective for electronic cam or electronic shaft
applications. Refer to the application examples in the user’s manual for the MP9
or MP2
Controllers from
Yaskawa for details.
Position