6.3 Main Commands

6-29

6.3.23 Servo OFF (SV_OFF: 32H)

Byte

SV_OFF

Description

Command

Response

1

32H

32H

Processing
classifications

Control com-
mand group

Synchronization
classifications

Asynchronous

2

ALARM

Processing time

*

Subcommand

Can be used

3

STATUS

• Turns the SERVOPACK OFF.
• Can be used during phases 2 and 3.
• During phase 1, a MECHATROLINK II command warning 1 (A.95A) will

occur and the command will be ignored.

* Processing time is set in Pn506 (Brake reference-servo off

delay time) ; 500 ms max.