5) connecting regenerative resistors, A) servopacks with capacities of 400 w or less, B) servopacks with capacities larger than 400w – Yaskawa SGDS Sigma III Servo Amplifier User Manual
Page 130: 27 (5) connecting regenerative resistors, Important, C n 2 c n 4 a / b

5.7 Connecting Regenerative Resistors
5-27
(5) Connecting Regenerative Resistors
(a) SERVOPACKs with Capacities of 400 W or Less
(b) SERVOPACKs with Capacities Larger than 400W
Do not touch the regenerative resistors because they reach high temperatures. Use heat-resistant, non-
flammable wiring and make sure that the wiring does not touch the resistors.
Refer to 4.1 SERVOPACK
Main Circuit Wire Size for connecting wire size when connecting an external regenerative resistor.
Connect an external regenerative resistor between
B1/
and B2 terminals.
Note: The user must provide the regenerative resis-
tor.
Disconnect the wiring between the SERVOPACK’s
B2 and B3 terminals and connect an external
regenerative resistor between the B1/
and B2
terminals.
The user must provide the regenerative resistor.
Note: Be sure to take out the lead wire between the
B2 and B3 terminals.
Enlarged View
YASKAWA SERVOPACK 2 0 0 V
S G D S - 0 2 A 1 2 A
SW1
CHARGE
L1
L2
L1C
L2C
B1/
B2
U
V
W
C
N
6
C
N
3
C
N
1
C
N
2
C
N
4
A / B
Enlarged View
L1C
L2C
B1/
B2
B3
U
+
− 1
− 2
CHARGE
CHARGE
IMPORTANT