Cavium Processor Complex

ATCA-9305 User’s Manual (10009109-07)

79

3.4.3

Diagnostic Tests During Power-up and Reset

The Cavium monitor diagnostic tests can be executed during power-up or invoked from the
monitor’s command prompt. This is accomplished by changing the state of the monitor
configuration parameters that define power-up and reset diagnostics mode. If the
powerondiags

parameter is set to “on”, the monitor invokes the diagnostic tests after a reset

of the hardware. Results are displayed to the console including whether the test passed or
failed.

3.4.3.1

POST Diagnostic Results

The ATCA-9305 Power-On Self-Test (POST) diagnostic results are stored as a 32-bit value in
memory accessible by the management console at location 0x80080A6C (where 0x80080A6C
is a 8548 or an Octeon address). Each bit indicates the result of a specific test, so this field can
store the results of up to 32 diagnostic tests.

Table 3-5

assigns the bits to specific tests.

3.4.4

Cavium Environment Variables

The following table lists the standard Cavium environment variables:

Table 3-5 POST Diagnostic Results–Bit Assignments

Bit

Diagnostic Test

Description

Value

0-1

Reserved

0 Passed the test
1 Failure detected

2

DRAM

Verify address and data lines are intact

3

Cavium BIST

-

4

I

2

C

Verify all local I

2

C devices are

connected to the I

2

C bus

5-31

Reserved

Table 3-6 Standard Cavium Environment Variables

Variable

Default Value

Description

baudrate

115200

Console port baud rate
Valid rates: 9600, 14400, 19200, 38400, 57600, 115200