3 diagnostic tests during power-up and reset, 1 post diagnostic results, 4 cavium environment variables – Artesyn ATCA-9305 User's Manual (May 2014) User Manual
Page 79: Table 3-5, Post diagnostic results–bit assignments, Table 3-6, Standard cavium environment variables, Cavium processor complex
![background image](https://www.manualsdir.com/files/772459/content/doc079.png)
Cavium Processor Complex
ATCA-9305 User’s Manual (10009109-07)
79
3.4.3
Diagnostic Tests During Power-up and Reset
The Cavium monitor diagnostic tests can be executed during power-up or invoked from the
monitor’s command prompt. This is accomplished by changing the state of the monitor
configuration parameters that define power-up and reset diagnostics mode. If the
powerondiags
parameter is set to “on”, the monitor invokes the diagnostic tests after a reset
of the hardware. Results are displayed to the console including whether the test passed or
failed.
3.4.3.1
POST Diagnostic Results
The ATCA-9305 Power-On Self-Test (POST) diagnostic results are stored as a 32-bit value in
memory accessible by the management console at location 0x80080A6C (where 0x80080A6C
is a 8548 or an Octeon address). Each bit indicates the result of a specific test, so this field can
store the results of up to 32 diagnostic tests.
assigns the bits to specific tests.
3.4.4
Cavium Environment Variables
The following table lists the standard Cavium environment variables:
Table 3-5 POST Diagnostic Results–Bit Assignments
Bit
Diagnostic Test
Description
Value
0-1
Reserved
0 Passed the test
1 Failure detected
2
DRAM
Verify address and data lines are intact
3
Cavium BIST
-
4
I
2
C
Verify all local I
2
C devices are
connected to the I
2
C bus
5-31
Reserved
Table 3-6 Standard Cavium Environment Variables
Variable
Default Value
Description
baudrate
115200
Console port baud rate
Valid rates: 9600, 14400, 19200, 38400, 57600, 115200