7.11.24 Update Discrete Sensor

The Update Discrete Sensor command is used to change the state of a discrete sensor
controlled by the payload.

Table 7-40 Update Discrete Sensor Command

Type

Byte

Data Field

Request Data

1:3

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)

4

Sensor ID identifies the payload-controlled discrete sensor that has
to be updated

5

Update flags
0 0=sensor initialization is complete
1=sensor is in the initial update state
1:2 reserved, set to 0
3 0=globally disable events from the sensor
1=leave the global event enable bit intact
4 0=globally enable events from the sensor
1=leave the global event enable bit intact
5 0=globally disable sensor scanning
1=leave the global scanning enable bit intact
6 0=globally enable sensor scanning
1=leave the global scanning enable bit intact
7 reserved, set to 0

6:7

New status LSB and new status MSB are the least and most
significant bytes of the new sensor state

Response Data

1

Completion Code

2:4

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)