3 basic operation, Table 9-1, Debug led codes – Artesyn ATCA-9305 User's Manual (May 2014) User Manual
Page 222: Management processor monitor
Management Processor Monitor
ATCA-9305 User’s Manual (10009109-07)
222
This prompt is also displayed as an indication that the monitor has finished executing a
command or function invoked at the command prompt (except when the command loads and
jumps to a user application). The hardware product name (ATCA-9305), and current software
version number are displayed in the prompt.
Prior to the console port being available, the monitor will display a four-bit hexadecimal value
on LED1 through LED4 to indicate the power-up status (see
). See
for the
debug LED locations. In the event of a specific initialization error, the LED pattern will be
displayed and the board initialization will halt.
9.3
Basic Operation
The monitor performs various configuration tasks upon power-up or reset. This section
describes the monitor operation during initialization of the ATCA-9305 board. The flowchart
(see
) illustrates the power-up and global reset sequence (bold text indicates
environment variables).
Table 9-1 Debug LED Codes
LED Code
Power-up Status
LED Value
BOARD_PRE_INIT
start booting, setup BATs done
0x01
SERIAL_INIT
console init done
0x02
CHECKBOARD
get processor and bus speeds done
0x03
SDRAM_INIT
RAM / ECC init done
0x04
AFTER_RELOC
U-Boot relocated to RAM done
0x05
MISC_R
final init including Ethernet done
0x06
GONE_TO_PROMPT
-
0x00