System management – Artesyn ATCA-9305 User's Manual (May 2014) User Manual

Page 158

background image

System Management

ATCA-9305 User’s Manual (10009109-07)

158

Response Data 3

Timer Actions
[7] reserved
[6:4] pretime-out interrupt
000b=none
001b=SMI
010b=NMI/Diagnostic Interrupt
011b=Messaging Interrupt (this would be the same interrupt as
allocated to the messaging interface)
100b, 111b =reserved
[3] reserved
[2:0] time-out action
000b=no action
001b=Hard Reset
010b=Power Down
011b=Power Cycle
100b, 111b=reserved

4

Pretime-out interval in seconds, ‘1’based

5

Timer Use Expiration flags (1b=timer expired while associated ‘use’ was
selected)
[7] reserved
[6] reserved
[5] OEM
[4] SMS/OS
[3] OS Load
[2] Monitor/POST
[1] Monitor FRB-2
[0] reserved

6

Initial countdown value, lsbyte (100 ms/count)

7

Initial countdown, msbyte

Table 7-10 Get Watchdog Timer Command (continued)

Type

Byte

Data Field