beautypg.com

1 get fru led properties command, Table 7-12, Get fru led properties command – Artesyn ATCA-9305 User's Manual (May 2014) User Manual

Page 160: System management

background image

System Management

ATCA-9305 User’s Manual (10009109-07)

160

7.10.1 Get FRU LED Properties Command

This command allows software to determine which LEDs are under IPMC control.

3

03

CR56

The amber LED is user defined.

Table 7-11 FRU LEDs

LEDs

ID (hex)

Reference Designator

Description

Table 7-12 Get FRU LED Properties Command

Type

Byte

Data Field

Request Data

1

PICMG Identifier—indicates that this is a PICMG defined group extension
command. Use value 00h.

2

FRU Device ID

Response Data

1

Completion Code

2

PICMG Identifier—indicates that this is a PICMG defined group extension
command. Use value 00h.

3

General Status LED Properties—indicates the FRU’s ability to control the
four general status LEDs. When a bit is set, the FRU can control the
associated LED.
Bits [7:4] reserved, set to 0
Bit [3] LED3
Bit [2] LED2
Bit [1] LED1
Bit [0] Blue LED

4

Application Specific LED Count—is the number of application specific
LEDs under IPMC control.
00h-FBh Number of application-specific LEDs under IPMC control. If
none are present, this field is 00h.
FCh-FFh reserved