Management Processor Monitor
ATCA-9305 User’s Manual (10009109-07)
226
Recovering the Monitor
1. Make sure that a monitor ROM device is installed in the PLCC socket on the ATCA-
9305.
2. Verify there is a shunt on J9, across pins 1 and 2.
3. Issue the following command, where serial_number is the board’s serial number, at
the monitor prompt:
ATCA-9305 (1.0) => moninit serial_number
moninit will also reset environment variables to the default state.
4. To boot from soldered flash, power down the board and remove the shunt from J9,
pins 1 and 2.
The monitor always resides in the top 1MB block of NOR flash (banks 1 and 2) as shown in
.
9.4.1
Resetting Environment Variables
To restore the monitor’s standard environment variables, execute the following commands
and insert the appropriate data in the italicized fields:
Table 9-3 Monitor Address per Flash Device
Address Range (hex)
Device
F3F8,0000-F400,0000
Monitor Location in Flash Bank2
F3B8,0000-F3C0,0000
Monitor Location in Flash Bank1
F3B7,0000-F3B7,1000
Environment Variables
F3F7,0000-F3F7,1000
Redundant Environment Variables