Response Data

1

Completion Code

2:4

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)

5

Local Control LED Function
00h LED is off (default if Local Control not supported)
01h-FAh LED is blinking Off duration specified by this byte, on
duration specified by byte 5 (in tens of milliseconds)
FBh-FEh reserved
FFh LED is on

6

Local Control On Duration
LED on-time is measured in tens of milliseconds
Lamp Test time in hundreds of milliseconds if byte 4=FBh, time value
must be less than 128. Other values when Byte 4=FBh are reserved.
Otherwise, this field is ignored and shall be set to 0h.

7

Color parameter specifies the color of the LED in the local state for
multi-color LEDs

8

If the off-first flag parameter is 0, the on part of the blink cycle of the
LED precedes the off part of the cycle. Otherwise, the off part of the
blink cycle precedes the on part of the cycle.

Table 7-39 Get Local FRU LED State Command (continued)

Type

Byte

Data Field