25 update threshold sensor, 12 asynchronous event notification, 25update threshold sensor – Artesyn ATCA-9305 User's Manual (May 2014) User Manual
Page 192: Table 7-41, Update threshold sensor command, System management

System Management
ATCA-9305 User’s Manual (10009109-07)
192
7.11.25 Update Threshold Sensor
The Update Threshold Sensor command is used to change the state of a threshold sensor
controlled by the payload.
7.12 ASYNCHRONOUS EVENT NOTIFICATION
To enable payload applications to be informed about graceful shutdown/reboot requests, the
FRU Activate (Deactivate) and FRU Control (Graceful Reboot) command message is routed as
a LUN2 message to the payload interface.
Table 7-41 Update Threshold Sensor Command
Type
Byte
Data Field
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
4
Sensor ID parameter identifies the payload-controlled threshold sensor
that has to be updated
Request Data
5
Update flags
0 0=sensor initialization is complete
1=sensor is in the initial update state
1:2 reserved, set to 0
3 0=globally disable events from the sensor
1=leave the global event enable bit intact
4 0=globally enable events from the sensor
1=leave the global event enable bit intact
5 0=globally disable sensor scanning
1=leave the global scanning enable bit intact
6 0=globally enable sensor scanning
1=leave the global scanning enable bit intact
7 reserved, set to 0
6
New raw reading of the sensor
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)