System Management

ATCA-9305 User’s Manual (10009109-07)

156

2

Timer Actions
[7] reserved
[6:4] pretime-out interrupt (logged on expiration when “don’t log”
bit = 0b)
000b=none
001b=SMI
011b=Messaging Interrupt (this is the same interrupt as
allocated to the messaging interface)
010b=NMI/Diagnostic Interrupt
100b, 111b =reserved
[3] reserved
[2:0] time-out action
000b=no action
001b=Hard Reset
010b=Power Down
011b=Power Cycle
100b, 111b=reserved

3

Pretime-out interval in seconds, ‘1’ based

Request Data
(continued)

4

Timer Use Expiration flags clear
(0b=leave alone, 1b=clear timer use expiration bit)
[7] reserved
[6] reserved
[5] OEM
[4] SMS/OS
[3] OS Load
[2] Monitor/POST
[1] Monitor FRB-2
[0] reserved

5

Initial countdown value, lsbyte (100 ms/count)

6

Initial countdown value, msbyte

Response Data

1

Completion Code

Table 7-9 Set Watchdog Timer Command (continued)

Type

Byte

Data Field