beautypg.com

10 get payload communication time-out, 10get payload communication time-out, Table 7-26 – Artesyn ATCA-9305 User's Manual (May 2014) User Manual

Page 178: Get payload communication time-out command, System management

background image

System Management

ATCA-9305 User’s Manual (10009109-07)

178

7.11.10 Get Payload Communication Time-Out

The Get Payload Communication Time-Out command reads the payload communication
time-out value.

Response Data

1

Completion Code

2:4

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)

Table 7-25 Set Handle Switch Command (continued)

Type

Byte

Data Field

Table 7-26 Get Payload Communication Time-Out Command

Type

Byte

Data Field

Request Data

1:3

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)

Response Data 1

Completion Code

2:4

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)

5

Payload Time-out
Payload communication time-out measured in hundreds of
milliseconds. Thus, the payload communication time-out may vary
from 0.1 to 25.5 seconds.