21 set payload shutdown time-out, 21set payload shutdown time-out, Table 7-36 – Artesyn ATCA-9305 User's Manual (May 2014) User Manual
Page 187: Get payload shutdown time-out command, Table 7-37, Set payload shutdown time-out command, System management

System Management
ATCA-9305 User’s Manual (10009109-07)
187
To avoid deadlocks that may occur if the payload software does not respond, the IPMC provides
a special time-out for the payload shutdown sequence. If the payload does not send the
Graceful Reset command within a definite period of time, the IPMC assumes that the payload
shutdown sequence is finished, and sends a Module Quiesced Hot Swap event to the ATCA-
9305 controller.
7.11.21 Set Payload Shutdown Time-Out
The Set Payload Shutdown Time-Out command is defined as follows:
Table 7-36 Get Payload Shutdown Time-Out Command
Type
Byte
Data Field
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
5:6
Time-Out measured in hundreds of milliseconds, LSB first
Table 7-37 Set Payload Shutdown Time-Out Command
Type
Byte
Data Field
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
4:5
Time-Out measured in hundreds of milliseconds, LSB first
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)