System Management

ATCA-9305 User’s Manual (10009109-07)

187

To avoid deadlocks that may occur if the payload software does not respond, the IPMC provides
a special time-out for the payload shutdown sequence. If the payload does not send the
Graceful Reset command within a definite period of time, the IPMC assumes that the payload
shutdown sequence is finished, and sends a Module Quiesced Hot Swap event to the ATCA-
9305 controller.

7.11.21 Set Payload Shutdown Time-Out

The Set Payload Shutdown Time-Out command is defined as follows:

Table 7-36 Get Payload Shutdown Time-Out Command

Type

Byte

Data Field

Request Data

1:3

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)

Response Data

1

Completion Code

2:4

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)

5:6

Time-Out measured in hundreds of milliseconds, LSB first

Table 7-37 Set Payload Shutdown Time-Out Command

Type

Byte

Data Field

Request Data

1:3

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)

4:5

Time-Out measured in hundreds of milliseconds, LSB first

Response Data

1

Completion Code

2:4

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)