7.11.23 Get Local FRU LED State

The Get Local FRU LED State command is used to read the local state of a FRU LED.

Response Data

1

Completion Code

2:4

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)

Table 7-38 Set Local FRU LED State Command (continued)

Type

Byte

Data Field

Table 7-39 Get Local FRU LED State Command

Type

Byte

Data Field

Request Data

1:3

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)

4

FRU Device ID

5

LED ID
00h Blue LED (Hot Swap)
01h LED 1 (OOS)
02h LED 2
03h LED 3
04h-FEh OEM defined LEDs
FFh reserved (all LEDs under management control are addressed)