beautypg.com

6 message bridging, Figure 7-3, Extension command response example – Artesyn ATCA-9305 User's Manual (May 2014) User Manual

Page 145: System management

background image

System Management

ATCA-9305 User’s Manual (10009109-07)

145

7.6

Message Bridging

The Message Bridging facility is responsible for bridging messages between various interfaces
of the ATCA-9305 IPMI. The message bridging is implemented via the standard Send Message
command.

The ATCA-9305 IPMC also supports message bridging between the Payload Interface and
IPMB-0, which allows the payload to send custom messages to and receive them from other
shelf entities, such as the shelf manager. Message bridging is implemented using the Send/Get
Message commands and also via LUN 10 of the ATCA-9305 IPMC.

The following example illustrates how the Send/Get Message and Get Address Info commands
can be used by the payload software to get the physical location of the board in the shelf:

1. The payload software sends the Get Address Info command to the BMR-H8S-AMCc,

requesting address information for FRU device 0. Using the SIPL protocol:
[B0 xx 01 00]

Figure 7-3

Extension Command Response Example

[BC 00 01 00 0A 40 00 34]

Command Code

rqSeq (00

16

) / Bridge (00

2

)

NetFn Code (2F

16

) / LUN (00

2

)

Pigeon Point IANA

Data

Completion Code