2 environmental considerations, Table 2-3, Environmental requirements – Artesyn ATCA-9305 User's Manual (May 2014) User Manual
Page 63: Setup
Setup
ATCA-9305 User’s Manual (10009109-07)
63
The exact power requirements for the ATCA-9305 circuit board depend upon the specific
configuration of the board, including the CPU frequency and amount of memory installed on
the board. Please contact Artesyn Technical Support at 1-888-412-7832 if you have specific
questions regarding the board’s power requirements.
2.3.2
Environmental Considerations
As with any printed circuit board, be sure that air flow to the board is adequate. Chassis
constraints and other factors greatly affect the air flow rate. The environmental requirements
are as follows:
Table 2-3 Environmental Requirements
Requirement
Operating
Non-Operating
Temperature
+5 ºC (+41 °F) to +40 ºC (+104 °F)
(normal operation) according to NEBS
Standard GR-63-CORE
-5 ºC (+23 °F) to +55 ºC (+131 °F)
(exceptional operation) according to
NEBS Standard GR-63-CORE
-40 ºC (-40 °F) to +70 ºC (+158 °F)
(may be further limited by installed
accessories)
Airflow
The blade is designed to operate in a
chassis that provides 35 CFM across the
blade for the stated temperature range.
-
Temp. change
+/- 0.5 ºC/min according to NEBS
Standard GR-63-CORE
+/- 0.5 ºC/min
Rel. humidity
5% to 90% non-condensing according to
Artesyn-internal environmental
requirements
5% to 95% non-condensing
according to Artesyn-internal
environmental requirements
Vibration
1 g from 5 to 100 Hz and back to 5 Hz at
a rate of 0.1 octave/minute
5-20 Hz at 0.1 g
2
/Hz
20-200 Hz at -3.0 dB/octave
Random 20-200 Hz at -3 m/Sec
2
Shock
Half-sine, 11 m/Sec, 30 mSec/sec
2
Blade level packaging
Half-sine, 6 mSec at 180 m/Sec
2
Free fall
1,200 mm/all edges and corners
1.0 m (packaged)
100 mm (unpacked)