beautypg.com

11 vendor commands, Table 7-16, Vendor command summary – Artesyn ATCA-9305 User's Manual (May 2014) User Manual

Page 167: System management

background image

System Management

ATCA-9305 User’s Manual (10009109-07)

167

7.11 Vendor Commands

The IPMC supports additional IPMI commands that are specific to Pigeon Point and/or Artesyn.
This section provides detailed descriptions of those extension or SIPL commands.

Response Data

10

Lamp Test Duration–is optional if Lamp Test is not in effect (hundreds of
milliseconds).

Table 7-15 Get FRU LED State Command (continued)

Type

Byte

Data Field

Table 7-16 Vendor Command Summary

Command

netFn

LUN

Cmd

Get Status

OEM

2E, 2F

00

Get Serial Interface Properties

OEM

2E, 2F

01

Set Serial Interface Properties

OEM

2E, 2F

02

Get Debug Level

OEM

2E, 2F

03

Set Debug Level

OEM

2E, 2F

04

Get Hardware Address

OEM

2E, 2F

05

Set Hardware Address

OEM

2E, 2F

06

Get Handle Switch

OEM

2E, 2F

07

Set Handle Switch

OEM

2E, 2F

08

Get Payload Communication Time-Out

OEM

2E, 2F

09

Set Payload Communication Time-Out

OEM

2E, 2F

0A

Enable Payload Control

OEM

2E, 2F

0B

Disable Payload Control

OEM

2E, 2F

0C

Reset IPMC

OEM

2E, 2F

0D

Hang IPMC

OEM

2E, 2F

0E

Bused Resource Control

OEM

2E, 2F

0F

Bused Resource Status

OEM

2E, 2F

10

Graceful Reset

OEM

2E, 2F

11