beautypg.com

System management – Artesyn ATCA-9305 User's Manual (May 2014) User Manual

Page 171

background image

System Management

ATCA-9305 User’s Manual (10009109-07)

171

Response Data

7

Bits [4:7] Clock Bus 2 Events
These bits indicate pending Clock Bus 2 requests arrived from the carrier
controller:
0 Clock Bus 2 Query
1 Clock Bus 2 Release
2 Clock Bus 2 Force
3 Clock Bus 2 Free
Bits [0:3] Clock Bus 1 Events
These bits indicate pending Clock Bus 1 requests arrived from the carrier
controller:
0 Clock Bus 1 Query
1 Clock Bus 1 Release
2 Clock Bus 1 Force
3 Clock Bus 1 Free

8

Bits [4:7] reserved
Bits [0:3] Clock Bus 3 Events
These bits indicate pending Clock Bus 3 requests arrived from the carrier
controller:
0 Clock Bus 3 Query
1 Clock Bus 3 Release
2 Clock Bus 3 Force
3 Clock Bus 3 Free

Table 7-17 Get Status Command (continued)

Type

Byte

Data Field