beautypg.com

3 set fru led state command, Table 7-14, Set fru led state command – Artesyn ATCA-9305 User's Manual (May 2014) User Manual

Page 163: System management

background image

System Management

ATCA-9305 User’s Manual (10009109-07)

163

7.10.3 Set FRU LED State Command

The Set FRU LED State command allows the state of the FRU LEDs to be controlled by the
management system.

Table 7-14 Set FRU LED State Command

Type

Byte

Data Field

Request Data

1

PICMG Identifier—indicates that this is a PICMG defined group extension
command. Use value 00h.

2

FRU Device ID

3

LED ID
00h Blue LED (Hot Swap)
01h LED 1 (OOS)
02h LED 2
03h LED 3
04h-FEh OEM defined LEDs
FFh Lamp Test (all LEDs under management control are addressed)

4

LED Function
00h LED off override
01h-FAh LED blinking override
FBh Lamp Test state Turn on LED specified in byte 3 for the duration
specified in byte 5, then return to the highest priority state.
FCh LED state restored to Local Control state
FDh-FEh reserved
FFh LED on override

5

On Duration
LED on-time is measured in tens of milliseconds
Lamp Test time in hundreds of milliseconds if byte 4=FBh, time value
must be less than 128. Other values when Byte 4=FBh are reserved.
Otherwise, this field is ignored and shall be set to 0h.