ATCA-9305 User’s Manual (10009109-07)

168

7.11.1 Get Status

The IPMC firmware notifies the payload about changes of all status bits except for bits 0-2 by
sending an unprintable character (ASCII 07, BELL) over the Payload Interface. The payload is
expected to use the Get Status command to identify pending events and other SIPL commands
to provide a response (if necessary). The event notification character is sent in a synchronous
manner, and does not appear in the contents of SIPL messages sent to the payload.

Diagnostic Interrupt Results

OEM

2E, 2F

12

Get Payload Shutdown Time-Out

OEM

2E, 2F

15

Set Payload Shutdown Time-Out

OEM

2E, 2F

16

Set Local FRU LED State

OEM

2E, 2F

18

Get Local FRU LED State

OEM

2E, 2F

19

Update Discrete Sensor

OEM

2E, 2F

1A

Update Threshold Sensor

OEM

2E, 2F

1B

Reserved for Message Listeners

OEM

2E, 2F

17

Add Message Listener

OEM

2E, 2F

18

Remove Message Listener

OEM

2E, 2F

19

Get Message Listener List

OEM

2E, 2F

1A

Update Firmware Progress Sensor

OEM

2E, 2F

F0

Table 7-16 Vendor Command Summary (continued)

Command

netFn

LUN

Cmd

Table 7-17 Get Status Command

Type

Byte

Data Field

Request Data

1:3

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)

Response Data 1

Completion Code

2:4

PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)