1 get status, Table 7-17, Get status command – Artesyn ATCA-9305 User's Manual (May 2014) User Manual
Page 168: System management

System Management
ATCA-9305 User’s Manual (10009109-07)
168
7.11.1 Get Status
The IPMC firmware notifies the payload about changes of all status bits except for bits 0-2 by
sending an unprintable character (ASCII 07, BELL) over the Payload Interface. The payload is
expected to use the Get Status command to identify pending events and other SIPL commands
to provide a response (if necessary). The event notification character is sent in a synchronous
manner, and does not appear in the contents of SIPL messages sent to the payload.
Diagnostic Interrupt Results
OEM
2E, 2F
12
Get Payload Shutdown Time-Out
OEM
2E, 2F
15
Set Payload Shutdown Time-Out
OEM
2E, 2F
16
Set Local FRU LED State
OEM
2E, 2F
18
Get Local FRU LED State
OEM
2E, 2F
19
Update Discrete Sensor
OEM
2E, 2F
1A
Update Threshold Sensor
OEM
2E, 2F
1B
Reserved for Message Listeners
OEM
2E, 2F
17
Add Message Listener
OEM
2E, 2F
18
Remove Message Listener
OEM
2E, 2F
19
Get Message Listener List
OEM
2E, 2F
1A
Update Firmware Progress Sensor
OEM
2E, 2F
F0
Table 7-16 Vendor Command Summary (continued)
Command
netFn
LUN
Cmd
Table 7-17 Get Status Command
Type
Byte
Data Field
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data 1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)