beautypg.com

Delta Electronics Elevator Drive VFD-VL User Manual

Page 83

background image

Chapter 4 Parameters|

4-28

Revision Nov. 2008, VLE1, SW V1.03

00-14

Source of the Master Frequency Command

Control

mode

VF

VFPG

SVC

FOCPG FOCPM

Factory setting: 1

Settings

1

RS-485 serial communication or digital keypad (KPVL-CC01)

2

External analog input (Pr. 03-00)

3

Digital terminals input (Pr.04-00~04-15)

This parameter determines the drive’s master frequency source.

00-15

Source of the Operation Command

Control

mode

VF

VFPG

SVC

FOCPG TQCPG FOCPM

Factory setting: 1

Settings

1

External terminals

2

RS-485 serial communication or digital keypad (KPVL-CC01)

VFD-VL series is shipped without digital keypad and users can use external terminals or RS-

485 to control the operation command.

When the LED PU is light, the operation command can be controlled by the optional digital

keypad (KPVL-CC01). Refer to appendix B for details.