beautypg.com

Delta Electronics Elevator Drive VFD-VL User Manual

Page 81

background image

Chapter 4 Parameters|

4-26

Revision Nov. 2008, VLE1, SW V1.03

Pass wor d Setting

Decoding F low Chart

F or getting Passwrod

00-08

Di splays 01 when

entering correct
password into

Pr.00-08.

Di splays 00 when

entering correct
password into

Pr.00-07.

00-08

After entering 9999, press

twice to decode. The parameter
setti ng wil l be set to fac tory s etting.

00-07

PROG

DATA


3 chances to enter the correct password.

1st time displays "01" if password is incorrect.
2nd time displays "02", if password is incorrect.

3rd time displays "P code"(blinking)

If the password was entered incorrectly after

three tries, the keypad will be locked.
Turn the power OFF/ON to re-enter the password.

Incorrect Password

END

Di splays 00 when

entering correct
password into

Pr.00-07.

Correct Password

END

00-07

00-08

00-08

00-07

00-09

Control Method

Control

mode

VF

VFPG

SVC

FOCPG TQCPG FOCPM

Factory Setting: 0

Settings

0

V/f

control

1

V/f + Encoder (VFPG)

2

Sensorless vector control (SVC)

3

FOC vector control + Encoder (FOCPG)

4

Torque control + Encoder (TQCPG)

8

FOC PM control (FOCPM)

This parameter determines the control method of the AC motor drive:

Setting 0: user can design V/f ratio by requirement and control multiple motors simultaneously.

Setting 1: User can use PG card with Encoder to do close-loop speed control.

Setting 2: To have optimal control characteristic by auto-tuning.

Setting 3: To increase torque and control speed precisely. (1:1000)

Setting 4: To increase accuracy for torque control.