Chapter 3 Operation and Start Up|

Revision Nov. 2008, VLE1, SW V1.03 3-15

Pr.07-19
Source of Torque
Offset

0: Disable
1: Analog input (Pr.03-00)
2: Torque offset setting (Pr.07-20)
3: Control by external terminal (by Pr.07-21 to Pr.07-23)

Pr.03-03
Analog Input Bias 1
(AUI1)

-100.0~100.0%

Pr.03-06
Positive/negative Bias
Mode (AUI1)

0: Zero bias
1: Lower than bias=bias
2: Greater than bias=bias
3: The absolute value of the bias voltage while serving as
the center
4: Serve bias as the center

Pr.03-09
Analog Input Gain 1
(AUI1)

-500.0~500.0%

NOTE: Pr.03-03, 03-06 and 03-09 are used to adjust the analog input signal.

07-19: Source of tor que offset
03-00~02: Analog input selections (AUI1/ACI/AUI2)

03-03~05: Analog input bias (AUI1/ACI/AUI2)
03-06~08: AUI1/ACI/A UI2 bias mode

07-19=1

Analog input
03-00~02

Bias mode
03-06~08


B ias

03-03~05

+

+/-

Analog input gain

03-09~11

Preload

4.

Setting of drive stop

Adjusting Pr.01-29, Pr.01-30 and Pr.11-06