beautypg.com

Delta Electronics Elevator Drive VFD-VL User Manual

Page 51

background image

Chapter 3 Operation and Start Up|

3-12

Revision Nov. 2008, VLE1, SW V1.03

„ Setting the acceleration/deceleration with Pr.01-23 and the setting 08 (the 1st, 2nd

acceleration/deceleration time selection) and 09 (the 3rd, 4th acceleration/deceleration

time selection) of multi-function input command Pr.02-01~02-08.

„ Settings of acceleration/deceleration time: Pr.01-12~Pr.01-19

NOTE: it is recommended to set the acceleration/deceleration time to the small value in the

trial run and execute smooth test after all the actions are correct.

„ Settings of S curve: Pr.01-24~Pr.01-30

NOTE: it is recommended to set the S curve time to 0 in trial run and execute smooth test

after all the actions are correct.

Accel Time 1

0.00~600.00 sec

Decel Time 1

0.00~600.00 sec

Accel Time 2

0.00~600.00 sec

Decel Time 2

0.00~600.00 sec

Accel Time 3

0.00~600.00 sec

Decel Time 3

0.00~600.00 sec

Accel Time 4

0.00~600.00 sec

Settings of Pr.01-12 to

Pr.01-19

Decel Time 4

0.00~600.00 sec

S-curve for Acceleration

Departure Time S1

0.00~25.00 sec

S-curve for Acceleration

Arrival Time S2

0.00~25.00 sec

S-curve for Deceleration

Departure Time S3

0.00~25.00 sec

S-curve for Deceleration

Arrival Time S4

0.00~25.00 sec

Mode Selection when

Frequency < Fmin

0: Output waiting
1: Zero-speed operation
2: Fmin (4th output

frequency setting)

Switch Frequency for

S3/S4 Changes to S5

0.00~120.00Hz

Settings of Pr.01-24 to

Pr.01-30

S-curve for Deceleration

Arrival Time S5

0.00~25.00 sec