Chapter 4 Parameters|

4-104

Revision Nov. 2008, VLE1, SW V1.03

Group 11 Advanced Parameters

11-00

System Control

Control

mode

FOCPG

FOCPM

Factory Setting: 0

Settings

Bit

0=0

No

function

Bit 0=1

ASR Auto tuning, PDFF enable

Bit

7=0

No

function

Bit 7=1

When position control is enabled, it doesn’t need to set Pr.07-02
(DC Brake Current Level)

Bit 15=0

when power is applied, it will detect the position of magnetic field
again

Bit 15=1

when power is applied, it will start from the magnetic field
position of previous power failure

Bit 0=1: PDFF function is enabled and system will generate an ASR setting, Pr. 10-11~10-16

will be invalid and Pr.11-09 to 11-10 will be valid.

YES

NO

Setting auto gain adjustment
Pr.11-00=1

Adjust Pr.11- 06, 11- 07 and 11- 08

separately by s peed response

Adjust by r equir ement
Pr.11-09, Pr. 11-10 (PDFF function)

Adjust by r equir ement Pr.10-17
(A SR1/ASR2 s wi tc h frequency)

Pr.10- 20: Zer o speed/ASR1 width adjustment
Pr.10- 21: ASR1/ASR2 width adjustment

Adjust by r equir ement Pr.07-25~28 (torque li mit)

Adjust gain value by manual
Pr.11-00=0 ( fac tor y s etting)

Adjust Pr.10-11, 10- 12, 10- 13,

10-14, 10-15 and 10-16
separately by s peed response

Adjust by r equir ement
Pr.10- 18 (for general,

no need to adjus t)

When Pr.11-00

is set B it 0=1