beautypg.com

Delta Electronics Elevator Drive VFD-VL User Manual

Page 196

background image

Appendix A Specifications|

Revision Nov. 2008, VLE1, SW V1.03 A-3

General Specifications

Control System

1: V/f, 2: VF+PG, 3: SVC, 4: FOC+PG, 5: TQR+PG, 6:FOC+PM

Start Torque

Starting torque is 150% at 0.5Hz and 0Hz with control modes FOC + PG and
FOC+PM

Speed Control Range

1:100 Sensorless vector (up to 1:1000 when using PG card)

Speed Control Resolution

±0.5% Sensorless vector (up to±0.02% when using PG card)

Speed Response Ability

5Hz (up to 30Hz for vector control)

Max. Output Frequency

0.00 to 120.00Hz

Output Frequency Accuracy

Digital command

±0.005%, analog command ±0.5%

Frequency Setting
Resolution

Digital command

±0.01Hz, analog command: 1/4096(12-bit) of the max. output

frequency

Torque Limit

Max. is 200% torque current

Torque Accuracy

±5%

Accel/Decel Time

0.00 to 600.00/0.0 to 6000.0 seconds

V/f Curve

Adjustable V/f curve using 4 independent points and square curve

Frequency Setting Signal

0-+10V,

±10V, 4~20mA

Co

n

tro

l Ch

a

ra

cte

ristics

Brake Torque

About 20%

Motor Protection

Electronic thermal relay protection

Over-current Protection

The current forces 220% of the over-current protection and 300% of the rated
current

Ground Leakage Current
Protection

Higher than 50% rated current

Overload Ability

Constant torque: 150% for 60 seconds, variable torque: 200% for 3 seconds

Over-voltage Protection

Over-voltage level: Vdc > 400/800V; low-voltage level: Vdc < 200/400V

Over-voltage Protection for
the Input Power

Varistor (MOV)

Over-temperature Protection Built-in temperature sensor

Pr

otecti

on

C

har

acter

ist

ics

Compensation for the
Momentory Power Loss

Up to 5 seconds for parameter setting

Protection Level

NEMA 1/IP20

Operation Temperature

-10°C to 45°C

Storage Temperature

-20°C to 60°C

Ambient Humidity

Below 90% RH (non-condensing)

Vibration 9.80665m/s

2

(1G) less than 20Hz, 5.88m/s

2

(0.6G) at 20 to 50Hz

Envi

ronm

en

tal

C

ondi

tions

Installation Location

Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust

Approvals